banenr

product

Co Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

Short Description:

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

Related Video

Feedback (2)

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of 220v Gas Detector Alarm, Gas Leak Detector Enclosure, Home Smoke And Gas Detector, Our organization has been devoting that "customer first" and committed to helping clients expand their small business, so that they become the Big Boss !
Co Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action Detail:

Background

In the process of using natural gas, various equipment and devices such as pipelines, gate stations, pressure regulating equipment, valve wells, etc. are involved. These complicated gas supply equipment and pipe networks have brought many problems to the management of gas companies, especially the management of gas valve wells. Gas valve wells can cause gas leakage due to equipment aging, faults, and improper operation of personnel. However, traditional manual inspections are difficult to rush to the site for effective treatment in the first time due to the inspection density and inspection effect. All these have brought challenges to the management of gas companies.

Product advantages

1) Using advanced laser sensors (tunable laser spectroscopy (TDLAS) technology) with low false alarm and the service life is up to 5-10 years;

2) Adopt NB-IoT communication and cooperate with mainstream operators such as China mobile and telecommunications to ensure reliable communication;

3) The whole machine is designed with low power consumption and long working time, which can effectively reduce the equipment maintenance cost.

Main features

1) Large-capacity battery(152Ah) of domestic first-line brand, reliable capacity;

2) Using advanced laser sensors (tunable laser spectroscopy (TDLAS) technology, with high reliability, strong anti-interference ability, low false alarm rate and maintenance free;

3) Adopt NB-IOT wireless remote transmission solution, low power consumption, wide coverage and strong connection ability;

4) Well cover abnormal alarm and emergency treatment to prevent accidents;

5) The flooding alarm function detects the equipment status and informs the user that the equipment is in the detection empty window period.

Technical specifications

Performance

Detected gas

Combustible gas(Methane)

Detection principle

Tunable diode laser absorption spectroscopy technology(TDLAS)

Alarm error

±3%LEL

Detection range

0 ~ 100%LEL

Indication error

±3%LEL(Displayed on the access platform)

Alarm setting value

Low limit:25%LEL; High limit:50%LEL

Response time(T90)

T90≤10s

Wireless communication

NB-IoT

Detection interval

60minutes(Standard working mode)

Communication interval

24hour(Standard working mode)

Reporting time

08:00(Default)

Protection grage

IP67

Explosion proof grade

ExdibⅡCT4 Gb

Sensor storage life (under normal storage environment)

5 years

Sensor service life (typical)

5 years

 

Electrical characteristic

Power supply

Disposable lithium battery power supply(152Ah)

Operating voltage

3.6VDC

Battery operating hours (under standard operating mode)

≥3years

Continue working time after battery under voltage (under standard working mode)

15days

Environmental parameters

Environmental pressure

86kPa~106kPa

Environment humidity

≤100%RH(No condensation)

Environment temperature

-40℃~+70℃

Storage environment

Storage temperature: -20℃~+30℃, relative humidity ≤60%RH, no corrosive substances on site

Structure characteristics

Dimensions

545mm×205mm×110mm

Material

Cast aluminum

Weight

About 6kg(including battery)

Installation mode

Wall mounted: bracket hanging and fixing

Stability

100mm drop resistance (with packaging)

Boundary Dimension

Mounting Mode


6.1 Detector installation mode:
When detecting combustible gas with lower specific weight than air such as methane, the detector shall be installed as close to the wellhead as possible (the distance from the wellhead shall not be more than 30cm)

6.2 Manhole cover displacement switch installation method
The manhole cover displacement switch is perpendicular to the ground plane, and the top of the manhole cover displacement switch trigger rod is more than 2cm higher than the manhole cover (as shown in the figure below). After installation, the switch can be triggered when the manhole cover is closed.


Product detail pictures:

Co Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action detail pictures

Co Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action detail pictures


Related Product Guide:

Attaining consumer satisfaction is our company's purpose without end. We will make wonderful endeavours to produce new and top-quality merchandise, satisfy your exclusive requirements and supply you with pre-sale, on-sale and after-sale services for Co Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action , The product will supply to all over the world, such as: Azerbaijan, Plymouth, Melbourne, We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.
The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
5 Stars By Karen from Doha - 2018.05.13 17:00
The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
5 Stars By Freda from Egypt - 2017.05.02 11:33
Write your message here and send it to us