Item |
Data |
Detected gases |
Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) |
Sampling mode |
Diffusive sampling |
Operating voltage |
DC24±6V |
Power consumption |
≤3W (DC24V) |
Display |
LCD display |
Calibration |
By keys or a remote controller |
Signal transmission distance |
≤1500m (2.5 mm2) |
Protection grade |
IP66 |
Explosion proof grade |
ExdⅡCT6Gb |
Signal transmission |
Three-wire (4~20)mA standard signals [support HART] and 3 sets of relay signals |
Outlet hole connecting thread |
NPT3/4"(female) |
Material |
Cast aluminum |
Dimension |
Length × width × height: 228mm×177mm×87mm |
Weight |
1.9 kg |
Highly-integrated functional module design
The integrated functional module is made up of two parts, i.e. detector module and sensor module. Anti-misplug standard digital interface is used between the two modules, good for on-site hot plug replacement;
Alarm concentration can be set freely within the full range
Low alarm concentration and high alarm concentration can be set freely within the full range. As keys are used for calibration, the calibrated value can be set according to calibrated gas concentration. Concentration is displayed through LCD on a real-time basis. On-site calibration can also be perfomed with an IR remote controller. At the time of calibration, it is unnecessary to open the cover. The operation is easy and convenient;
Military-grade LCD display
LCD real-time concentration display, clearly indicating equipment working conditions under highlight and in distance;
Multiple communication modes are available
Such product types as three-wire (4-20mA), two-wire (4-20mA), and 4-20mA with HART are available for selection;
Flexible combination and multiple output modes
Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;
Replace a sensor as easy as replacing a bulb
Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost.
Model |
Signal output |
Sensor equipped |
Adaptive control system |
AEC2338 |
Three-wire (4~20)mA standard signal (supporting HART) and three sets of relay signals
Two-wire (4~20)mA standard signal (supporting HART) |
Catalytic combustion, semiconductor, electrochemical, IR & PID |
ACTION gas alarm controllers: AEC2392a, AEC2392b, AEC2393a , AEC2393b2a-BS, AEC2393b2a-BM |