Performance indicators |
|||
Type of detected gas |
Methane |
Principle of detected |
Tunable diode laser absorption spectroscopy technology (TDLAS) |
Detected distance |
100m |
Detected range |
(0~100000)ppm·m |
Basic error |
±1%FS |
Response time (T90) |
≤0.1s |
Sensitivity |
5ppm.m |
Protection grade |
IP68 |
Explosion-proof grade |
Exd ⅡC T6 Gb/DIP A20 TA,T6 |
Detect laser safety grade |
Class I |
Indicate laser safety grade |
classⅢR (Human eyes cannot look directly) |
|
Electrical characteristics |
|||
Operating voltage |
220VAC (recommended) or 24VDC |
Maximum current |
≤1A |
Power consumption |
≤100W |
Communication |
Single core optical fiber (it is recommended to lay more than 4-core optical fiber cables on site) |
Structure characteristics |
|||
Dimensions (Length × height × width) |
529mm×396mm×320mm |
Weight |
About 35kg |
Installation mode |
Vertical installation |
Material |
304 Stainless steel |
Environmental parameters |
|||
Environmental pressure |
80kPa~106kPa |
Environmental humidity |
0~98%RH (No condensation) |
Environmental temperature |
-40℃~60℃ |
|
PTZ parameters |
|||
Horizontal rotation |
(0°±2)~(360°±2) |
Vertical rotation |
-(90°±2)~(90°±2) |
Horizontal rotation speed |
0.1°~20°/S Smooth variable speed rotation |
Vertical rotation speed |
0.1°~20°/S Smooth variable speed rotation |
Preset position speed |
20°/S |
Preset position quantity |
99 |
Preset position precision |
≤0.1° |
Automatic heating |
Automatic heating when below -10℃ |
PTZ control communication method |
RS485 |
PTZ control communication rate |
9600bps |
PTZ control communication protocol |
Pelco protocol |
|
Camera parameters |
|||
Type of Sensor |
1/2.8″ CMOS ICR day night type |
Signal system |
PAL/NSTC |
Shutter |
1/1second ~ 1/30,000 second |
Day night conversion mode |
ICR Infrared filter type |
Resolution |
50HZ:25fps(1920X1080) 60HZ:30fps(1920X1080) |
Minimum illumination |
Color:0.05Lux @ (F1.6,AGC ON) Black and white:0.01Lux @ (F1.6,AGC ON) |
Signal to noise ratio |
>52dB |
White balance |
Auto1/Auto2/Indoor/Outdoor/Manual/Incandescent/Fluorescent |
3D Noise reduction |
Support |
Focal length |
Focal length: 4.8-120mm |
Aperture |
F1.6-F3.5 |
|
● Cloud Bench Laser Methane Detector, realize continuous scanning and monitoring in a wide range of areas with 360 ° horizontal and 180 ° vertical;
● Fast response speed, high detection accuracy, and timely find small leakage;
● It has unique selectivity for target gas, good stability and daily maintenance free;
● 220VAC working voltage, RS485 data signal output, optical fiber video signal output;
● Multi preset position setting, cruise route can be set freely;
● With special software, it can scan, locate and record the location of leakage source.