banenr

product

  • Carbon Monoxide Detector Gas Leak GT-AEC2338 Fixed Gas Detector – Action

    Carbon Monoxide Detector Gas Leak GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Propane Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Propane Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Gas Detection Device AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Gas Detection Device AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Product Selling Point 1) 4 ~ 20mA standard signal, supporting HART protocol Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol 2) Highly-integrated functional module design The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The ...
  • Refrigerant Gas Leak Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Refrigerant Gas Leak Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Product Selling Point 1) 4 ~ 20mA standard signal, supporting HART protocol Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol 2) Highly-integrated functional module design The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The ...
  • Fixed Gas Detection System Regulation AEC2323 Explosion-proof Audible-visual Alarm – Action

    Fixed Gas Detection System Regulation AEC2323 Explosion-proof Audible-visual Alarm – Action

    General The AEC2323 explosion-proof audible-visual alarm is a small audible-visual alarm applicable to zone-1 and 2 hazardous areas and class-IIA, IIB, IIC explosive gas environment with a temperature class of T1-T6. The product has a stainless steel enclosure and a red PC lampshade. It is characterized by high intensity, impact resistantance, and high explosion-proof grade. Its LED luminescent tube is characterized by highlight, long service life and non-maintenance. With a G3/4’’ pipe ...
  • Catalytic Gas Detector AEC2323 Explosion-proof Audible-visual Alarm – Action

    Catalytic Gas Detector AEC2323 Explosion-proof Audible-visual Alarm – Action

    General The AEC2323 explosion-proof audible-visual alarm is a small audible-visual alarm applicable to zone-1 and 2 hazardous areas and class-IIA, IIB, IIC explosive gas environment with a temperature class of T1-T6. The product has a stainless steel enclosure and a red PC lampshade. It is characterized by high intensity, impact resistantance, and high explosion-proof grade. Its LED luminescent tube is characterized by highlight, long service life and non-maintenance. With a G3/4’’ pipe ...
  • Household Gas Detector GT-AEC2331a Industrial and commercial combustible gas detector – Action

    Household Gas Detector GT-AEC2331a Industrial and commercial combustible gas detector – Action

    Technical Parameters Item Data Detected gases Natural gas Principle of detection Catalytic combustion Sampling mode Diffusive sampling Range 3-100%LEL Operating voltage DC24±6V Power consumption ≤1W (DC24V) Electrical interface NPT3/4" Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Shell Cast aluminum Dimension Length × width × thickness: 110mm×103mm×55mm Weight About 530g Major Features High ...
  • Co Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Co Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Gas Detection Monitor GT-AEC2232bX-p Fixed Gas Detector – Action

    Gas Detection Monitor GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Gas Leakage Monitoring System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Gas Leakage Monitoring System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Cheap Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Cheap Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Gas Detector Methane GT-AEC2331a Industrial and commercial combustible gas detector – Action

    Gas Detector Methane GT-AEC2331a Industrial and commercial combustible gas detector – Action

    Technical Parameters Item Data Detected gases Natural gas Principle of detection Catalytic combustion Sampling mode Diffusive sampling Range 3-100%LEL Operating voltage DC24±6V Power consumption ≤1W (DC24V) Electrical interface NPT3/4" Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Shell Cast aluminum Dimension Length × width × thickness: 110mm×103mm×55mm Weight About 530g Major Features High ...