banenr

product

  • So2 Gas Monitor AEC2323 Explosion-proof Audible-visual Alarm – Action

    So2 Gas Monitor AEC2323 Explosion-proof Audible-visual Alarm – Action

    General The AEC2323 explosion-proof audible-visual alarm is a small audible-visual alarm applicable to zone-1 and 2 hazardous areas and class-IIA, IIB, IIC explosive gas environment with a temperature class of T1-T6. The product has a stainless steel enclosure and a red PC lampshade. It is characterized by high intensity, impact resistantance, and high explosion-proof grade. Its LED luminescent tube is characterized by highlight, long service life and non-maintenance. With a G3/4’’ pipe ...
  • Gas Leak Detector Portable BT-AEC2689 Series Handheld Laser Methane Telemeter – Action

    Gas Leak Detector Portable BT-AEC2689 Series Handheld Laser Methane Telemeter – Action

    Technical Parameters Item Data Detected gas Methane Detected methods Remote detection Response time ≤0.1s Detected distance 0-150m Detected range 0-100000ppm.m Detected laser grade Class I Indicate laser grade Class IIIR not look directly Continuous working hours ≥8h Protection grade IP54 Explosion-proof grade Ex ib IIC T4 Gb Operating temperature -20℃~+50℃ Major Features Strong anti-interference ability It adopts ad...
  • Gas Detection Tube AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Gas Detection Tube AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Product Selling Point 1) 4 ~ 20mA standard signal, supporting HART protocol Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol 2) Highly-integrated functional module design The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The ...
  • Security Alarm System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Security Alarm System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Co Detector Gas Leak GT-AEC2338 Fixed Gas Detector – Action

    Co Detector Gas Leak GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Carbon Monoxide Detector Gas Leak AEC2323 Explosion-proof Audible-visual Alarm – Action

    Carbon Monoxide Detector Gas Leak AEC2323 Explosion-proof Audible-visual Alarm – Action

    General The AEC2323 explosion-proof audible-visual alarm is a small audible-visual alarm applicable to zone-1 and 2 hazardous areas and class-IIA, IIB, IIC explosive gas environment with a temperature class of T1-T6. The product has a stainless steel enclosure and a red PC lampshade. It is characterized by high intensity, impact resistantance, and high explosion-proof grade. Its LED luminescent tube is characterized by highlight, long service life and non-maintenance. With a G3/4’’ pipe ...
  • Combustible Gas Detection Controller AEC2305 Small Capacity Gas Alarm Controller – Action

    Combustible Gas Detection Controller AEC2305 Small Capacity Gas Alarm Controller – Action

    Technical Specifications Operating voltage  AC176V~AC264V (50Hz±1%) Power consumption  ≤10W (excluding supporting equipment) Environmental condition for operating  temperature 0℃~+40℃, relative humidity≤93%RH Signal transmission  four-bus system (S1, S2, +24V and GND) Signal transmission distance  ≤1500m (2.5mm2) Types of gas detected  %LEL Capacity  1~2 Adaptive equipment  gas detectors :GT-AEC2331a, GT-AEC2232a,GT-AEC2232bX/A Input module  JB-MK-AEC2241 (d) Fan l...
  • Gas Leak Detector System GT-AEC2232bX-p Fixed Gas Detector – Action

    Gas Leak Detector System GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Portable Gas Detection GT-AEC2536 cloud bench laser methane detector – Action

    Portable Gas Detection GT-AEC2536 cloud bench laser methane detector – Action

    Technical Parameters Performance indicators Type of detected gas Methane Principle of detected Tunable diode laser absorption spectroscopy technology (TDLAS) Detected distance 100m Detected range (0~100000)ppm·m Basic error ±1%FS Response time (T90) ≤0.1s Sensitivity 5ppm.m Protection grade IP68 Explosion-proof grade Exd ⅡC T6 Gb/DIP A20 TA,T6 Detect laser safety grade Class I Indicate laser safety grade classⅢR (Human eyes can...
  • Portable Hydrogen Gas Detector GT-AEC2536 cloud bench laser methane detector – Action

    Portable Hydrogen Gas Detector GT-AEC2536 cloud bench laser methane detector – Action

    Technical Parameters Performance indicators Type of detected gas Methane Principle of detected Tunable diode laser absorption spectroscopy technology (TDLAS) Detected distance 100m Detected range (0~100000)ppm·m Basic error ±1%FS Response time (T90) ≤0.1s Sensitivity 5ppm.m Protection grade IP68 Explosion-proof grade Exd ⅡC T6 Gb/DIP A20 TA,T6 Detect laser safety grade Class I Indicate laser safety grade classⅢR (Human eyes can...
  • Portable Toxic Gas Leak Detector BT-AEC2387 Portable Single Gas Detector – Action

    Portable Toxic Gas Leak Detector BT-AEC2387 Portable Single Gas Detector – Action

    Product Selling Point 1) Detection of various gases: by matching sensors with different gas types and ranges, it can quickly meet the detection needs of different customers in different places; 2) Compact body: the body is light and small, easy to carry, and can be placed in a pocket or pinned to the chest to release both hands; 3) LCD display: real-time display of gas concentration, intuitively understand the state, concentration and other information of the measured gas; 4) Simple operation...
  • Multi Gas Monitors DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Multi Gas Monitors DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Background In the process of using natural gas, various equipment and devices such as pipelines, gate stations, pressure regulating equipment, valve wells, etc. are involved. These complicated gas supply equipment and pipe networks have brought many problems to the management of gas companies, especially the management of gas valve wells. Gas valve wells can cause gas leakage due to equipment aging, faults, and improper operation of personnel. However, traditional manual inspections are ...