banenr

product

  • Co Detector Natural Gas GT-AEC2232bX-p Fixed Gas Detector – Action

    Co Detector Natural Gas GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Gas Detector System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Gas Detector System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Gas Leak And Carbon Monoxide Detector GT-AEC2338 Fixed Gas Detector – Action

    Gas Leak And Carbon Monoxide Detector GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Detector De Gas GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Detector De Gas GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • House Alarm System Home Security JT-AEC2363a Household Combustible Gas Detector – Action

    House Alarm System Home Security JT-AEC2363a Household Combustible Gas Detector – Action

    Product Selling Point 1) High cost performance: minimalist appearance, focused functions, eliminating redundant design, focusing on the product itself, and striving to bring the ultimate user experience; 2) Output mode: single output, driving household solenoid valve, forming a cost-effective household gas safety solution; 3) Quick response: response time≤10S Product Parameter Characteristics Principle of detection Semiconductor Detection mode Diffusive Detectable gases Meth...
  • Security Alarm System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Security Alarm System GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Toxic Gas Analyzer GT-AEC2338 Fixed Gas Detector – Action

    Toxic Gas Analyzer GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Gas Leak Detector Enclosure GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Gas Leak Detector Enclosure GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • H2 Gas Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    H2 Gas Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Background In the process of using natural gas, various equipment and devices such as pipelines, gate stations, pressure regulating equipment, valve wells, etc. are involved. These complicated gas supply equipment and pipe networks have brought many problems to the management of gas companies, especially the management of gas valve wells. Gas valve wells can cause gas leakage due to equipment aging, faults, and improper operation of personnel. However, traditional manual inspections are ...
  • Home Gas Detector DN15 Household Gas Solenoid Valve – Action

    Home Gas Detector DN15 Household Gas Solenoid Valve – Action

    Technical parameters Item Data Medium type Natural gases, liquefied gases, artificial coal gases and non-corrosive gases Rated voltage DC9V capacity discharge Working mode Normally open Drift diameter DN15 Time to cut off <0.3s Working pressure ≤50 kPa Atmospheric pressure 86 kPa~106kPa Operating environment temperature -10℃~+60℃ Relative humidity ≤93% Explosion-proof grade Exmb IIBT6Gb Reset mode Manual reset V...
  • Hazardous Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Hazardous Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • High Precision Combustible Gas Leak Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    High Precision Combustible Gas Leak Gas Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...