banenr

product

  • Chlorine Gas Monitor AEC2323 Explosion-proof Audible-visual Alarm – Action

    Chlorine Gas Monitor AEC2323 Explosion-proof Audible-visual Alarm – Action

    General The AEC2323 explosion-proof audible-visual alarm is a small audible-visual alarm applicable to zone-1 and 2 hazardous areas and class-IIA, IIB, IIC explosive gas environment with a temperature class of T1-T6. The product has a stainless steel enclosure and a red PC lampshade. It is characterized by high intensity, impact resistantance, and high explosion-proof grade. Its LED luminescent tube is characterized by highlight, long service life and non-maintenance. With a G3/4’’ pipe ...
  • Fixed Gas Detection GT-AEC2338 Fixed Gas Detector – Action

    Fixed Gas Detection GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Portable Gas Leak Detector BT-AEC2387 Portable Single Gas Detector – Action

    Portable Gas Leak Detector BT-AEC2387 Portable Single Gas Detector – Action

    Product Selling Point 1) Detection of various gases: by matching sensors with different gas types and ranges, it can quickly meet the detection needs of different customers in different places; 2) Compact body: the body is light and small, easy to carry, and can be placed in a pocket or pinned to the chest to release both hands; 3) LCD display: real-time display of gas concentration, intuitively understand the state, concentration and other information of the measured gas; 4) Simple oper...
  • Smart Combustible Gas Detector GT-AEC2338 Fixed Gas Detector – Action

    Smart Combustible Gas Detector GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Gas Detector Uae AEC2323 Explosion-proof Audible-visual Alarm – Action

    Gas Detector Uae AEC2323 Explosion-proof Audible-visual Alarm – Action

    General The AEC2323 explosion-proof audible-visual alarm is a small audible-visual alarm applicable to zone-1 and 2 hazardous areas and class-IIA, IIB, IIC explosive gas environment with a temperature class of T1-T6. The product has a stainless steel enclosure and a red PC lampshade. It is characterized by high intensity, impact resistantance, and high explosion-proof grade. Its LED luminescent tube is characterized by highlight, long service life and non-maintenance. With a G3/4’’ pipe ...
  • Gas Detector Alarm GT-AEC2232bX-p Fixed Gas Detector – Action

    Gas Detector Alarm GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • Carbon Monoxide Detector Detect Gas Leak DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Carbon Monoxide Detector Detect Gas Leak DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Background In the process of using natural gas, various equipment and devices such as pipelines, gate stations, pressure regulating equipment, valve wells, etc. are involved. These complicated gas supply equipment and pipe networks have brought many problems to the management of gas companies, especially the management of gas valve wells. Gas valve wells can cause gas leakage due to equipment aging, faults, and improper operation of personnel. However, traditional manual inspections are ...
  • Gas Leakage Detector With Valve GT-AEC2338 Fixed Gas Detector – Action

    Gas Leakage Detector With Valve GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Carbon Monoxide Natural Gas Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Carbon Monoxide Natural Gas Detector DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Background In the process of using natural gas, various equipment and devices such as pipelines, gate stations, pressure regulating equipment, valve wells, etc. are involved. These complicated gas supply equipment and pipe networks have brought many problems to the management of gas companies, especially the management of gas valve wells. Gas valve wells can cause gas leakage due to equipment aging, faults, and improper operation of personnel. However, traditional manual inspections are ...
  • Gas Control Panel AEC2305 Small Capacity Gas Alarm Controller – Action

    Gas Control Panel AEC2305 Small Capacity Gas Alarm Controller – Action

    Technical Specifications Operating voltage  AC176V~AC264V (50Hz±1%) Power consumption  ≤10W (excluding supporting equipment) Environmental condition for operating  temperature 0℃~+40℃, relative humidity≤93%RH Signal transmission  four-bus system (S1, S2, +24V and GND) Signal transmission distance  ≤1500m (2.5mm2) Types of gas detected  %LEL Capacity  1~2 Adaptive equipment  gas detectors :GT-AEC2331a, GT-AEC2232a,GT-AEC2232bX/A Input module  JB-MK-AEC2241 (d) Fan l...
  • Home Gas Monitor DN15 Household Gas Solenoid Valve – Action

    Home Gas Monitor DN15 Household Gas Solenoid Valve – Action

    Technical parameters Item Data Medium type Natural gases, liquefied gases, artificial coal gases and non-corrosive gases Rated voltage DC9V capacity discharge Working mode Normally open Drift diameter DN15 Time to cut off <0.3s Working pressure ≤50 kPa Atmospheric pressure 86 kPa~106kPa Operating environment temperature -10℃~+60℃ Relative humidity ≤93% Explosion-proof grade Exmb IIBT6Gb Reset mode Manual reset V...
  • Alarms For Home JT-AEC2363a Household Combustible Gas Detector – Action

    Alarms For Home JT-AEC2363a Household Combustible Gas Detector – Action

    Product Selling Point 1) High cost performance: minimalist appearance, focused functions, eliminating redundant design, focusing on the product itself, and striving to bring the ultimate user experience; 2) Output mode: single output, driving household solenoid valve, forming a cost-effective household gas safety solution; 3) Quick response: response time≤10S Product Parameter Characteristics Principle of detection Semiconductor Detection mode Diffusive Detectable gases Meth...