banenr

product

  • Gas Detector Price GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Gas Detector Price GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Refrigerant Gas Leak Detector GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Refrigerant Gas Leak Detector GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Detector Fugas Gas Natural DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Detector Fugas Gas Natural DT-AEC2531 Combustible Gas Monitoring Device for Underground Well Room – Action

    Background In the process of using natural gas, various equipment and devices such as pipelines, gate stations, pressure regulating equipment, valve wells, etc. are involved. These complicated gas supply equipment and pipe networks have brought many problems to the management of gas companies, especially the management of gas valve wells. Gas valve wells can cause gas leakage due to equipment aging, faults, and improper operation of personnel. However, traditional manual inspections are ...
  • Fixed Gas Detection System Regulation AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Fixed Gas Detection System Regulation AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Product Selling Point 1) 4 ~ 20mA standard signal, supporting HART protocol Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol 2) Highly-integrated functional module design The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The ...
  • Marine Gas Detector GT-AEC2338 Fixed Gas Detector – Action

    Marine Gas Detector GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • Toxic Gas Leak Detector GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Toxic Gas Leak Detector GT-AEC2335 AC220V Powered Fixed Gas Detector – Action

    Technical specifications Item Data Detected gases Natural gas, Propane Principle of detection Catalytic combustion Sampling mode Diffusive sampling Detected range (0~100)%LEL Response time ≤12s Operating voltage AC176V~AC264V (50Hz±1%) Power consumption ≤4W Alarming mode Buzzer alarming and indicator alarming Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Service life of the sensor Three years (typical) ...
  • Four In One Gas Detector GT-AEC2232a Series Fixed Gas Detector – Action

    Four In One Gas Detector GT-AEC2232a Series Fixed Gas Detector – Action

    Product Selling Point 1) Beautiful and compact design Small design, Small size, more space saving; 2) Modular design The sensor can be hot-swapped and replaced, reducing the follow-up maintenance cost of the product. Especially for electrochemical sensors with a short life, it can save users a lot of replacement costs; 3) Can be equipped with explosion-proof audible and visual alarm It can be equipped with ACTION explosion-proof audible and visual alarm to meet the needs of users for aud...
  • Medical Gas Pipeline System In Hospitals AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Medical Gas Pipeline System In Hospitals AEC2232bX Series Toxic & Combustible Gas Detector – Action

    Product Selling Point 1) 4 ~ 20mA standard signal, supporting HART protocol Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol 2) Highly-integrated functional module design The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The ...
  • Portable Natural Gas Leak Detector BT-AEC2387 Portable Single Gas Detector – Action

    Portable Natural Gas Leak Detector BT-AEC2387 Portable Single Gas Detector – Action

    Product Selling Point 1) Detection of various gases: by matching sensors with different gas types and ranges, it can quickly meet the detection needs of different customers in different places; 2) Compact body: the body is light and small, easy to carry, and can be placed in a pocket or pinned to the chest to release both hands; 3) LCD display: real-time display of gas concentration, intuitively understand the state, concentration and other information of the measured gas; 4) Simple oper...
  • Ac Gas Leak Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Ac Gas Leak Detector GT-AEC2232bX-p Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases VOC gases Sampling mode Pump suction Operating voltage DC24±6V Power consumption ≤3.5W (DC24V) Electrical interface NPT3/4"(female) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Outer casing Stainless steel + cast aluminum (shell: cast aluminum) Dimension Length × width ×thickness: 242.5mm×177mm×87mm Weight About 2.5 kg Major Features Patented compound PID joi...
  • H2s Gas Monitor GT-AEC2338 Fixed Gas Detector – Action

    H2s Gas Monitor GT-AEC2338 Fixed Gas Detector – Action

    Technical Parameters Item Data Detected gases Combustible gases and steams, toxic and hazardous gases (see A01, A03 and B04~B29 in the list of detectable gases) Sampling mode Diffusive sampling Operating voltage DC24±6V Power consumption ≤3W (DC24V) Display LCD display Calibration By keys or a remote controller Signal transmission distance ≤1500m (2.5 mm2) Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Signal transm...
  • 4 Gas Monitor GT-AEC2331a Industrial and commercial combustible gas detector – Action

    4 Gas Monitor GT-AEC2331a Industrial and commercial combustible gas detector – Action

    Technical Parameters Item Data Detected gases Natural gas Principle of detection Catalytic combustion Sampling mode Diffusive sampling Range 3-100%LEL Operating voltage DC24±6V Power consumption ≤1W (DC24V) Electrical interface NPT3/4" Protection grade IP66 Explosion proof grade ExdⅡCT6Gb Shell Cast aluminum Dimension Length × width × thickness: 110mm×103mm×55mm Weight About 530g Major Features High ...