banenr

product

Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action

Short Description:

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

Related Video

Feedback (2)

Our products are broadly regarded and reliable by end users and can meet up with constantly transforming financial and social requires of Co H2s O2 Ch4 Gas Detector, Detecting Natural Gas Leaks, Portable Gas Monitors, We also ensure that your selection will be crafted with the highest quality and reliability. Please feel free to contact us for further information.
Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action Detail:

Product Selling Point

1) 4 ~ 20mA standard signal, supporting HART protocol

Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol

2) Highly-integrated functional module design

The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The detector module is for power supply, communication and output functions;

3) Overlimit protection for high concentration

In case of overlimit of high concentration gas, the sensor module can cut off power supply automatically. Detection works every 30s until the concentration is normal and power supply is resumed. This function can prevent reduction of the sensor’s service life resulted from being submerged in high concentration gas;

4) Standardized digital interface

Standard digital interfaces are used between modules. Anti-misplug gold-plated pins are good for on-site hot plug replacement;

5) Flexible combination and multiple output modes

Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

6) Replace a sensor as easy as replacing a bulb

Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost;

7) On-site LED concentration display, and diversified calibration modes

Highlight LED real-time concentration display, with farther and wider visual distance and angle, applicable to industrial environment requirements; the detector can be set/calibrated in different ways, such as by keys or by an IR remote controller or a magnetic bar, and it is easy to operate;

8) Explosion-proof design

Enclosure of this product is made of cast aluminum or stainless steel materials and its explosion proof grade reaches Exd II CT6 Gb.

Product Parameter Characteristics

Optional sensor

Catalytic combustion, Semiconductor, Electrochemical, Infrared ray(IR), Photoion(PID)

Sampling mode

Diffusive sampling

Operating voltage

DC24V±6V

Alarm error

Combustible gases

±3%LEL

Indication error

Combustible gases

±3%LEL

 

toxic and hazardous gases

Alarm setting value ±15%, O2:±1.0%VOL

 

toxic and hazardous gases

±3%FS ( toxic and hazardous gases), ±2%FS (O2)

Power consumption

3W(DC24V)

Signal transmission distance

≤1500m(2.5mm²)

Press range

86kPa~106kPa

Humidity range

≤93%RH

Explosion proof grade

ExdⅡCT6

Protection grade

IP66

Electrical interface

NPT3/4" internal thread

Shell material

cast aluminum or stainless steel

Operating temperature

Catalytic combustion, Semiconductor, Infrared ray(IR): -40℃~+70℃; Electrochemical:  -40℃~+50℃; Photoion(PID):-40℃~+60℃

Optional signal transmission mode

1) A-BUS+ four-bus system signal and contact outputs of two sets of relays

2) Three-wire (4~20)mA standard signals and contact outputs of three sets of relays

Note:

(4~20) mA standard signal is {maximum load resistance: <250Ω(18VDC~20VDC), <500Ω(20VDC~30VDC)}

The relay signal is {alarm relay passive normally open contact output; fault relay passive normally closed contact output (contact capacity: DC24V /1A)}

Alarm concentration

The factory alarm setting value is different due to different sensors, the alarm concentration can be set arbitrarily in the full range, please consult




Product detail pictures:

Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures


Related Product Guide:

Innovation, good quality and reliability are the core values of our enterprise. These principles today extra than ever form the basis of our success as an internationally active mid-size organization for Gas Alarm AEC2232bX Series Toxic & Combustible Gas Detector – Action , The product will supply to all over the world, such as: Atlanta, Belarus, Grenada, The quality of our merchandise is equal to OEM's quality, because our core parts are the same with OEM supplier. The above items have passed professional certification, and we not only can produce OEM-standard items but we also accept Customized Merchandise order.
The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
5 Stars By Elaine from Vietnam - 2018.12.05 13:53
Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
5 Stars By Beulah from Hamburg - 2017.08.16 13:39
Write your message here and send it to us