banenr

product

Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action

Short Description:

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

Related Video

Feedback (2)

The corporation upholds the philosophy of "Be No.1 in excellent, be rooted on credit rating and trustworthiness for growth", will proceed to provide aged and new buyers from home and abroad whole-heatedly for Natural Gas Leak Detector, Gas Detection Monitor, Multi Gas Detector On Ship, Hope we can create a more glorious future with you through our efforts in the future.
Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action Detail:

Product Selling Point

1) 4 ~ 20mA standard signal, supporting HART protocol

Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol

2) Highly-integrated functional module design

The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The detector module is for power supply, communication and output functions;

3) Overlimit protection for high concentration

In case of overlimit of high concentration gas, the sensor module can cut off power supply automatically. Detection works every 30s until the concentration is normal and power supply is resumed. This function can prevent reduction of the sensor’s service life resulted from being submerged in high concentration gas;

4) Standardized digital interface

Standard digital interfaces are used between modules. Anti-misplug gold-plated pins are good for on-site hot plug replacement;

5) Flexible combination and multiple output modes

Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

6) Replace a sensor as easy as replacing a bulb

Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost;

7) On-site LED concentration display, and diversified calibration modes

Highlight LED real-time concentration display, with farther and wider visual distance and angle, applicable to industrial environment requirements; the detector can be set/calibrated in different ways, such as by keys or by an IR remote controller or a magnetic bar, and it is easy to operate;

8) Explosion-proof design

Enclosure of this product is made of cast aluminum or stainless steel materials and its explosion proof grade reaches Exd II CT6 Gb.

Product Parameter Characteristics

Optional sensor

Catalytic combustion, Semiconductor, Electrochemical, Infrared ray(IR), Photoion(PID)

Sampling mode

Diffusive sampling

Operating voltage

DC24V±6V

Alarm error

Combustible gases

±3%LEL

Indication error

Combustible gases

±3%LEL

 

toxic and hazardous gases

Alarm setting value ±15%, O2:±1.0%VOL

 

toxic and hazardous gases

±3%FS ( toxic and hazardous gases), ±2%FS (O2)

Power consumption

3W(DC24V)

Signal transmission distance

≤1500m(2.5mm²)

Press range

86kPa~106kPa

Humidity range

≤93%RH

Explosion proof grade

ExdⅡCT6

Protection grade

IP66

Electrical interface

NPT3/4" internal thread

Shell material

cast aluminum or stainless steel

Operating temperature

Catalytic combustion, Semiconductor, Infrared ray(IR): -40℃~+70℃; Electrochemical:  -40℃~+50℃; Photoion(PID):-40℃~+60℃

Optional signal transmission mode

1) A-BUS+ four-bus system signal and contact outputs of two sets of relays

2) Three-wire (4~20)mA standard signals and contact outputs of three sets of relays

Note:

(4~20) mA standard signal is {maximum load resistance: <250Ω(18VDC~20VDC), <500Ω(20VDC~30VDC)}

The relay signal is {alarm relay passive normally open contact output; fault relay passive normally closed contact output (contact capacity: DC24V /1A)}

Alarm concentration

The factory alarm setting value is different due to different sensors, the alarm concentration can be set arbitrarily in the full range, please consult




Product detail pictures:

Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures


Related Product Guide:

We'll make every effort and hard work to be superb and excellent, and speed up our steps for standing inside the rank of intercontinental top-grade and high-tech enterprises for Gas Co Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action , The product will supply to all over the world, such as: Berlin, Saudi Arabia, India, We'll supply much better products with diversified designs and expert services. We sincerely welcome friends from over the world to visit our company and cooperate with us on the basis of long-term and mutual benefits.
It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
5 Stars By Danny from Niger - 2018.10.09 19:07
As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
5 Stars By Edwina from Niger - 2018.12.10 19:03
Write your message here and send it to us