banenr

product

H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action

Short Description:

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

Related Video

Feedback (2)

We insist on offering premium quality creation with very good company concept, honest product sales along with the finest and fast assistance. it will bring you not only the premium quality item and huge profit, but the most significant is to occupy the endless market for 5 Gas Monitor, Gas Leak Detector Alarm, Four Gas Monitors, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action Detail:

Product Selling Point

1) 4 ~ 20mA standard signal, supporting HART protocol

Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol

2) Highly-integrated functional module design

The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The detector module is for power supply, communication and output functions;

3) Overlimit protection for high concentration

In case of overlimit of high concentration gas, the sensor module can cut off power supply automatically. Detection works every 30s until the concentration is normal and power supply is resumed. This function can prevent reduction of the sensor’s service life resulted from being submerged in high concentration gas;

4) Standardized digital interface

Standard digital interfaces are used between modules. Anti-misplug gold-plated pins are good for on-site hot plug replacement;

5) Flexible combination and multiple output modes

Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;

6) Replace a sensor as easy as replacing a bulb

Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost;

7) On-site LED concentration display, and diversified calibration modes

Highlight LED real-time concentration display, with farther and wider visual distance and angle, applicable to industrial environment requirements; the detector can be set/calibrated in different ways, such as by keys or by an IR remote controller or a magnetic bar, and it is easy to operate;

8) Explosion-proof design

Enclosure of this product is made of cast aluminum or stainless steel materials and its explosion proof grade reaches Exd II CT6 Gb.

Product Parameter Characteristics

Optional sensor

Catalytic combustion, Semiconductor, Electrochemical, Infrared ray(IR), Photoion(PID)

Sampling mode

Diffusive sampling

Operating voltage

DC24V±6V

Alarm error

Combustible gases

±3%LEL

Indication error

Combustible gases

±3%LEL

 

toxic and hazardous gases

Alarm setting value ±15%, O2:±1.0%VOL

 

toxic and hazardous gases

±3%FS ( toxic and hazardous gases), ±2%FS (O2)

Power consumption

3W(DC24V)

Signal transmission distance

≤1500m(2.5mm²)

Press range

86kPa~106kPa

Humidity range

≤93%RH

Explosion proof grade

ExdⅡCT6

Protection grade

IP66

Electrical interface

NPT3/4" internal thread

Shell material

cast aluminum or stainless steel

Operating temperature

Catalytic combustion, Semiconductor, Infrared ray(IR): -40℃~+70℃; Electrochemical:  -40℃~+50℃; Photoion(PID):-40℃~+60℃

Optional signal transmission mode

1) A-BUS+ four-bus system signal and contact outputs of two sets of relays

2) Three-wire (4~20)mA standard signals and contact outputs of three sets of relays

Note:

(4~20) mA standard signal is {maximum load resistance: <250Ω(18VDC~20VDC), <500Ω(20VDC~30VDC)}

The relay signal is {alarm relay passive normally open contact output; fault relay passive normally closed contact output (contact capacity: DC24V /1A)}

Alarm concentration

The factory alarm setting value is different due to different sensors, the alarm concentration can be set arbitrarily in the full range, please consult




Product detail pictures:

H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures

H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action detail pictures


Related Product Guide:

Our purpose is to fulfill our clients by offering golden company, great price and premium quality for H2 Gas Detector AEC2232bX Series Toxic & Combustible Gas Detector – Action , The product will supply to all over the world, such as: Ottawa, Irish, Rwanda, Now we have a excellent team supplying specialist service, prompt reply, timely delivery, excellent quality and best price to our customers. Satisfaction and good credit to every customer is our priority. We have been sincerely looking forward to cooperate with customers all over the world. We believe we can satisfy with you. We also warmly welcome customers to visit our company and purchase our solutions.
The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
5 Stars By Prudence from Iceland - 2018.07.12 12:19
The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
5 Stars By Laurel from Ethiopia - 2017.08.18 11:04
Write your message here and send it to us