banenr

product

Hot Selling for China Wall Mounted LPG Co O2 H2s Gas Leak Alarm Control Panel RS485 Controller

Short Description:

The 19” standard 3U panel-mounted all-metal rack has a slideway plug-in design in each channel; the standard 3U cabinet installation is characterized by easy installation, small volume (73% of AEC2392a) and anti-EMI/RFI interference;

The master control card and channel cards are set separately but have a function of synchronous display. With a large LCD Chinese display screen, the master control card can realize Chinese menu operation as well as faster and easier display and operation;

Channel cards can work independently under an independent menu. Thus, failure of the master control card or failure of other channel cards will not have an impact on normal channel cards’ gas monitoring;

Channel cards can receive 4-20mA signal or switching value signal input and be connected with various devices, including combustible gas detectors, toxic and hazardous gas detectors, oxygen detectors, flame detectors, smoke/heat detectors and manual alarming buttones, etc.;

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

We know that we only thrive if we can easily guarantee our combined price competiveness and excellent advantageous at the same time for Hot Selling for China Wall Mounted LPG Co O2 H2s Gas Leak Alarm Control Panel RS485 Controller, As a key organization of this industry, our corporation makes initiatives to become a leading supplier, according to the faith of qualified top quality & around the globe service.
We know that we only thrive if we can easily guarantee our combined price competiveness and excellent advantageous at the same time for China H2s Gas Detector Controller, Gas Detector Controller, LPG Co O2 H2s Gas Leak Alarm Control Panel, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which might be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we will continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.

Technical Specifications

Item  

Data

Power supply card

AC176V~AC264V (50Hz±1%)

Standard configuration (10 circuits)

one master control card, one power supply card, nine channel cards and one 19’’ standard 3U rack

Boundary dimension of the standard rack

19″ standard 3U rack (length x width x height: 483mm x 252mm x 132.5mm)
Configuration

One master control card, nine channel cards and one 19’’ standard 3U rack

Boundary dimension of the rack

19″ standard 3U rack (length× width × height: 483mm×252mm×132.5mm)

Item

Master control card

Channel card

Operating power supply

DC24V±6V

Types of gas detected

%LEL/%VOL/ppm

Range

(0~100)%LEL, (0~100)%VOL, (0~9999)ppm

Value indication error

±5%FS

Operating mode

Connected to channel cards or working independently

Connected to the master control card or working independently

Capacity

10, to connect 9 channel cards; the master control card can connect one set of 4-20mA standard current signal

One channel card connects one 4-20mA transmitter

Power consumption

3W

1W/channel card

Input signals

Connect to (4~20)mA standard current signals or passive switching value signals locally or via a channel card

4~20mA standard current signals or passive switching value signals

Output signals

1. RS485 bus communication signal (standard MODBUS protocol);2. Signals of 3 sets of relays (relays 1, 2 and 3); contact capacity: AC250V/10A or DC30V/10A. One channel card can output:Signals of 3 sets of relays (high alarm, low alarm and failure); contact capacity: AC250V/10A or DC30V/10A

Environmental condition for operating

Temperature: 0℃~+40℃; relative humidity: ≤93%; atmospheric pressure: 86kPa~106kPa

Alarming mode

Audible alarm and LED visual alarm

LED visual alarm

Display mode

OLCD Chinese display

LCD segment code display

Gross weight

About 4.5kg (excluding standby power supply)

Switch power supply

AC176V~AC264V (50Hz±0.5Hz); under voltage test point 170V±10V; main power supply’s max. working current: 1A

External standby power supply

DC12V /7Ah×2 lead-acid battery (external case)

Mounting mode

Standard 19” cabinet panel mounting

Note: The default system input signals are (4~20)mA standard signals; when the input signal is a passive switching value signal, the default signal is a passive normally-open signal; if a user requires that the default signal should be a passive normally-close signal under such case, please specify when ordering.

Major Features

● The 19” standard 3U panel-mounted all-metal rack has a slideway plug-in design in each channel; the standard 3U cabinet installation is characterized by easy installation, small volume (73% of AEC2392a) and anti-EMI/RFI interference;

● The master control card and channel cards are set separately but have a function of synchronous display. With a large LCD Chinese display screen, the master control card can realize Chinese menu operation as well as faster and easier display and operation;

● Channel cards can work independently under an independent menu. Thus, failure of the master control card or failure of other channel cards will not have an impact on normal channel cards’ gas monitoring;

● Channel cards can receive 4-20mA signal or switching value signal input and be connected with various devices, including combustible gas detectors, toxic and hazardous gas detectors, oxygen detectors, flame detectors, smoke/heat detectors and manual alarming buttones, etc.;

● Channel cards’ multiple output types are applicable to linkage of on-site external control devices, good for integration of the host control system (e.g. DCS, PLC, etc.);

● The master control card integrates the functions of the power supply card and the one-circuit channel card. All channels can be equipped with a HART communication module, showing a strong function;

● Strong output driving capacity; each circuit’s output capacity is up to 8W, to drive the integrated detector of audible and visual alarms and display;

● The master control card integrates the functions of the power supply card of the former 292a and the one-circuit channel card. All channels can be equipped with a HART communication module, showing a strong function;

● Channel cards have a three-color backlight LCD, which can indicate normal, failure and alarming status clearly;

● With an OLED screen and an aluminum alloy wortle panel, this product looks beautiful and magnificent generally.

Control Panel


The gas control panel contains the display interfaces and operating interfaces of the master control card and channel cards, including the display screen, the LED status indicator, the alarm buzzer (installed inside the master control card) and operating keys. The master control card has ten operating keys while a channel card has three ones (see the following diagram):

External interface

The master control card connects 9 circuits of channel cards. Each channel card collects 4-20mA multi-line or passive switching value signal output communication equipment, such as GT-AEC2232bX, GQ-AEC2232bX, GT-AEC2232aT, AEC2338, GQ-AEC2232bX-P, AEC2338-D detectors and flame detectors. It can also connect other 4-20mA output transmitters. Two sets of built-in modules of the master control card can realize remote linkage of external devices (on-site sound and light, solenoid valves and fans, etc.). External devices (e.g. on-site sound and light) can also be controlled through three sets of relay signal output terminals provided by each channel card. Remote communication with the host system can be done through the RS485 communication interface so that the host system can monitor AEC2393a gas detection systems in several areas intensively.

External interface

● Master control card:

F1+, F2-; LA1+, LA2-yyyyyyy; HA1+, HA2-: (3 sets) output terminals for relay external control signals output terminals

A+ and B-: RS485 communication interface connection terminals

L, PG and N: AC220V power supply terminals

B+ and B-: connection terminals of standby power supply

+24V, SIN and GND: input terminals for 4~20mA or passive switching value signals

● Channel card:

NC (normally closed), COM (Common) and NO (normally open): (3sets) output terminals for relay external control signals output terminals

24V, SIN and GND: input terminals for 4~20mA or passive switching value signals

When the signal connected is a passive switching value signal, the two ends of the signal are connected to 4~20mA (IN) and +24V. If DC24V power will be supplied to the equipment connected, the wiring is as shown in the system configuration diagram.

Internal terminal:

CAH, CAL, VSS and 24V: connection terminals for internal communication (connected in the factory)

Notes: (1) the maximum allowable wire diameter for connection terminals is 2.5mm2. (2) Factory default of the master control card’s relay output is passive switching value signal.

We know that we only thrive if we can easily guarantee our combined price competiveness and excellent advantageous at the same time for Hot Selling for China Wall Mounted LPG Co O2 H2s Gas Leak Alarm Control Panel RS485 Controller, As a key organization of this industry, our corporation makes initiatives to become a leading supplier, according to the faith of qualified top quality & around the globe service.
Hot Selling for China H2s Gas Detector Controller, Gas Detector Controller, LPG Co O2 H2s Gas Leak Alarm Control Panel, In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which might be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we will continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.


  • Previous:
  • Next:

  • Write your message here and send it to us