Being a result of ours specialty and service consciousness, our corporation has won a very good status amid buyers all over the world for ODM Manufacturer High Standard Fixed Type CH4 Gas Detector for Hazardous Area, We, with open arms, invite all interested potential buyers to visit our web-site or get in touch with us immediately for further information and facts.
Being a result of ours specialty and service consciousness, our corporation has won a very good status amid buyers all over the world for China CH4 gas detector and fixed gas detector, We accomplish this by exporting our wigs directly from our own factory to you. The goal of our company is to get customers who enjoy coming back to their business. We sincerely hope to cooperate with you in the near future. If there’s any opportunity, welcome to visit our factory!!!
1) 4 ~ 20mA standard signal, supporting HART protocol
Lightweight design, three wire system (4 ~ 20) mA standard signal, using first-line brand imported sensor, supporting HART protocol
2) Highly-integrated functional module design
The sensor module integrates a sensor and a processing circuit, to complete all data operation and signal switching of the detector independently. Its unique heating function expands the detector’s low temperature service capability. The detector module is for power supply, communication and output functions;
3) Overlimit protection for high concentration
In case of overlimit of high concentration gas, the sensor module can cut off power supply automatically. Detection works every 30s until the concentration is normal and power supply is resumed. This function can prevent reduction of the sensor’s service life resulted from being submerged in high concentration gas;
4) Standardized digital interface
Standard digital interfaces are used between modules. Anti-misplug gold-plated pins are good for on-site hot plug replacement;
5) Flexible combination and multiple output modes
Multiple detector modules and multiple types of sensor modules can be combined flexibly to form detectors with special output functions and applicable to different targets to meet customers’ customized demands;
6) Replace a sensor as easy as replacing a bulb
Sensor modules for different gases and ranges can be replaced freely. No calibration is required after replacement. That is, the detector can read ex-factory calibrated data and work immediately. In this way, the product has a longer service life. Meanwhile, detection calibration can be done easily at different sites, avoiding complicated dismantling process and difficult on-site calibration and reducing later maintenance cost;
7) On-site LED concentration display, and diversified calibration modes
Highlight LED real-time concentration display, with farther and wider visual distance and angle, applicable to industrial environment requirements; the detector can be set/calibrated in different ways, such as by keys or by an IR remote controller or a magnetic bar, and it is easy to operate;
8) Explosion-proof design
Enclosure of this product is made of cast aluminum or stainless steel materials and its explosion proof grade reaches Exd II CT6 Gb.
Optional sensor |
Catalytic combustion, Semiconductor, Electrochemical, Infrared ray(IR), Photoion(PID) |
||||
Sampling mode |
Diffusive sampling |
Operating voltage |
DC24V±6V |
||
Alarm error |
Combustible gases |
±3%LEL |
Indication error |
Combustible gases |
±3%LEL |
toxic and hazardous gases |
Alarm setting value ±15%, O2:±1.0%VOL |
toxic and hazardous gases |
±3%FS ( toxic and hazardous gases), ±2%FS (O2) | ||
Power consumption |
3W(DC24V) |
Signal transmission distance |
≤1500m(2.5mm²) |
||
Press range |
86kPa~106kPa |
Humidity range |
≤93%RH |
||
Explosion proof grade |
ExdⅡCT6 |
Protection grade |
IP66 |
||
Electrical interface |
NPT3/4" internal thread |
Shell material |
cast aluminum or stainless steel |
||
Operating temperature |
Catalytic combustion, Semiconductor, Infrared ray(IR): -40℃~+70℃; Electrochemical: -40℃~+50℃; Photoion(PID):-40℃~+60℃ |
||||
Optional signal transmission mode |
1) A-BUS+ four-bus system signal and contact outputs of two sets of relays
2) Three-wire (4~20)mA standard signals and contact outputs of three sets of relays Note: (4~20) mA standard signal is {maximum load resistance: <250Ω(18VDC~20VDC), <500Ω(20VDC~30VDC)} The relay signal is {alarm relay passive normally open contact output; fault relay passive normally closed contact output (contact capacity: DC24V /1A)} |
||||
Alarm concentration |
The factory alarm setting value is different due to different sensors, the alarm concentration can be set arbitrarily in the full range, please consult |
Being a result of ours specialty and service consciousness, our corporation has won a very good status amid buyers all over the world for ODM Manufacturer High Standard Fixed Type CH4 Gas Detector for Hazardous Area, We, with open arms, invite all interested potential buyers to visit our web-site or get in touch with us immediately for further information and facts.
ODM Manufacturer China CH4 gas detector and fixed gas detector, We accomplish this by exporting our wigs directly from our own factory to you. The goal of our company is to get customers who enjoy coming back to their business. We sincerely hope to cooperate with you in the near future. If there’s any opportunity, welcome to visit our factory!!!