banenr

product

PriceList for Industrial Fixed Ammonia Leak Detector

Short Description:

The 19” cabinet standard 3U panel-mounted all-metal structure can prevent EMI/RFI interference. Due to an independent plug-in card design, optional channel cards, master control cards and power supply cards can be used as required to set up a gas monitoring system with up to 1,000 point locations;

The master control card is characterized by LCD Chinese display and character menu operation. It can monitor the system’s concentration, alarm and failure statuses. It can also be used to set and search various parameters. It can set system time, range (%LEL, ppm and %VOL), three alarm types, alarm concentration, password, and operating authorization and search up to 999 alarm and failure records and 100 startup/shutdown records;

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

Innovation, top quality and reliability are the core values of our company. These principles today extra than ever form the basis of our success as an internationally active mid-size company for PriceList for Industrial Fixed Ammonia Leak Detector, “Making the Products of Significant Quality” will be the eternal objective of our business. We make unremitting attempts to notice the purpose of “We Will Always Preserve in Pace together with the Time”.
Innovation, top quality and reliability are the core values of our company. These principles today extra than ever form the basis of our success as an internationally active mid-size company for China Fixed Gas Detector and Alarm System, Whether selecting a current product from our catalog or seeking engineering assistance for your application, you can talk to our customer service center about your sourcing requirements. We can provided good quality with competitive price for you.

Technical Specifications

Item  

Data

Power supply card

AC176V~AC264V (50Hz±1%)

Standard configuration (8 circuits)

one master control card, one power supply card, eight channel cards and one 19’’ standard 3U rack

Boundary dimension of the standard rack

length × width × height 450mm×300mm×132.5mm (excluding handrail); 482mm×344mm×132.5mm (including handrail)

Item

Master control card

Channel card

Operating voltage

DC24V±6V

Power consumption

3W

0.5W/ Channel card

Environmental condition for operating

Temperature-10℃~+50℃; relative humidity≤93%RH; atmospheric pressure 86kPa~106kPa

Input signals

Connect to (4~20)mA standard current signals or passive switching value signals via a channel card

(4~20)mA standard current signals or passive switching value signals

Signal transmission distance

1500m (1.5mm2)

Types of gas detected

%LEL/%VOL/ppm

Operating mode

Working with channel cards

Connected to the master control card or working independently

Capacity

Connecting eight channel cards (expandable to 34 points)

One channel card connects one circuit of input

Adaptive equipment

Gas detectors: GT-AEC2232bX, GQ-AEC2232bX, GT-AEC2232aT, AEC2338, GQ-AEC2232bX –P, AEC2338-D Fan linkage box: JB-ZX-AEC2252F Solenoid valve linkage box: JB-ZX-AEC2252BFlame detectors, smoke/heat detectors and manual alarm buttons, etc.

Output signals

1. RS485 bus communication signal (standard MODBUS protocol);2. Signals of 2 sets of relays (failure and alarm); contact capacity: AC220V/5A or DC24V/5A One channel card can output:1. One set of (4~20)mA current signal;2. Signals of 3 sets of relays (high alarm, low alarm and failure); contact capacity: AC220V/5A or DC24V/5A

Alarm setting

Low alarm and high alarm

low alarm and high alarm

Alarming mode

Audible-visual alarm

Visual alarm

Display mode

LCD Chinese display

LED digital display

Mounting mode

Standard 19” cabinet panel mounting

Optional

Standby power supply  DC12V/7Ah×2 lead-acid battery (external case)

 Blind plate length × width: 129.5mm×35.2mm

Major Features

● The 19” cabinet standard 3U panel-mounted all-metal structure can prevent EMI/RFI interference. Due to an independent plug-in card design, optional channel cards, master control cards and power supply cards can be used as required to set up a gas monitoring system with up to 1,000 point locations;

● The master control card is characterized by LCD Chinese display and character menu operation. It can monitor the system’s concentration, alarm and failure statuses. It can also be used to set and search various parameters. It can set system time, range (%LEL, ppm and %VOL), three alarm types, alarm concentration, password, and operating authorization and search up to 999 alarm and failure records and 100 startup/shutdown records;

● The master control card’s RS485 bus communication interface, equipped with a standard MODBUS protocol, can communicate with the host control systems and connect fire and gas systems to improve the system integration level;

● Channel cards can receive 4-20mA signal or switching value signal input and be connected with various devices, including combustible gas detectors, toxic and hazardous gas detectors, oxygen detectors, flame detectors, smoke/heat detectors and manual alarming buttons, etc.;

● With a LED display accuracy of 0.000-9999, channel cards can monitor external equipment’s concentration, alarm and failure statuses on a real-time basis and communicate with the master control card. Channel cards can also work independently and be used to set parameters of detectors. Thus, failure of the master control card or failure of other channel cards will not have an impact on channel cards’ gas monitoring;

● Channel cards’ multiple output types are applicable to linkage of various on-site external control devices, good for integration of the host control system;

● Power supply cards supply DC24V power supply to internal devices of the host computer and on-site devices (in case of higher capacity, use special-purpose firefighting power supply).

Structure

1. 19” standard 3U rack 
2. 4×φ7.5 mounting hole
3. Handle
4. Channel card  
5. Channel card LED window
6. Screw
7. Lock switch of the standby power supply
8. Lock switch of the main power supply
9. Power supply card
10. Master control card
11. Master control card LCD panel

Wiring Diagram

Connection terminals:

Master control card:  

NO (normally open) and COM (common): (2 sets) output terminals for relay external control signals output terminals

A+, PGND and B-: RS485 communication interface connection terminals

Power supply card:

L, PE and N: AC220V power supply terminals

B+ and GND: connection terminals of standby power supply

Channel card: 

F1+ and F2-: connection terminals for relay signal output in case that a detector is faulty

LA1+ and LA2-: connection terminals for relay signal output in case that a detector gives a low alarm

HA1+ and HA2-: connection terminals for relay signal output in case that a detector gives a high alarm

GND and 4~20mA (OUT): (4~20) mA signal output terminals

GND, 4~20mA (IN) and +24V: input terminals for (4~20) mA or passive switching value signals

Internal terminal: no operation required

B and A: Connection terminals for internal communication

GND and 24V-IN: DC24 power supply terminals

Innovation, top quality and reliability are the core values of our company. These principles today extra than ever form the basis of our success as an internationally active mid-size company for PriceList for Industrial Fixed Ammonia Leak Detector, “Making the Products of Significant Quality” will be the eternal objective of our business. We make unremitting attempts to notice the purpose of “We Will Always Preserve in Pace together with the Time”.
PriceList for China Fixed Gas Detector and Alarm System, Whether selecting a current product from our catalog or seeking engineering assistance for your application, you can talk to our customer service center about your sourcing requirements. We can provided good quality with competitive price for you.


  • Previous:
  • Next:

  • Write your message here and send it to us