banenr

product

Professional China Combustible Gas Detection Controller - Gas Alarm Controller AEC2392b – Action

Short Description:

ACTION gas detectors are OEM & ODM supported and true mature devices, long-tested in millions of projects domestic and overseas since 1998! Don't hesitant to leave your any inquiry here!


Product Detail

Product Tags

Related Video

Feedback (2)

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" and the theory of "quality the basic, belief the very first and management the advanced" for Carbon Monoxide Detector Gas Leak, Cooking Gas Leak Detector, Gas Monitor Lel, Our experienced specialized group will be wholeheartedly at your support. We sincerely welcome you to check out our site and enterprise and send out us your inquiry.
Professional China Combustible Gas Detection Controller - Gas Alarm Controller AEC2392b – Action Detail:

Technical Specifications

Item  

Data

Operating voltage

AC220V±15% (50Hz±1%)

Capacity

1~4 points

Types of gas detected

%LEL, 10-6, %VOL and switching value signals

Range

Combustible gas: max. 100 (%LEL)

Toxic gas: max. 9,999 (10-6)

Oxygen: max. 100 (%VOL)

Power consumption

≤10W (excluding supporting equipment)

Load capacity

the max. output current of a single service circuit 24V ≤300mA

Environmental condition for operating

Temperature: 0℃~40℃; relative humidity≤93%RH

Alarming mode

audible-visual alarm

Value indication error

±5%FS

Alarming error

±15% of the alarming concentration

Display mode

nixie tube

Signal transmission

4~20mA standard signal (three-wire system)

Signal transmission distance

≤1000m (1.5mm2)

Output

five sets of relay contact signals, with the capacity of 10A/DC24V or 10A/AC220V

RS485 bus interface (standard MODBUS protocol)

Boundary dimensions

Length × width × thickness: 365mm×220mm×97mm

Gross weight

about 6kg

Standby power supply

12VDC/2Ah×2

Mounting mode

wall-mounted

Adaptive detectors

Gas detectors: GT-AEC2232bX,

GQ-AEC2232bX, GT-AEC2232aT, AEC2338, GQ-AEC2232bX -P, AEC2338-D

Fan linkage box: JB-ZX-AEC2252F

Solenoid valve linkage box: JB-ZX-AEC2252B

Major Features

● Meet the need of connecting standard 4-20mA current signal detectors at 1-4 point locations;

● With a small size, the product can be wall-mounted easily. Two sets or more can be installed side by side to meet customer’s demands for more point locations (wall mounting of 8, 12, 16 or more point locations can be realized through gapless combination);

● Monitoring and display of real-time concentration (%LEL, 10-6, %VOL) as well as switching value signals of combustible gas, toxic gas and oxygen (default is combustible gas detector. No setting is required. It is available for use after being installed and electrified);

● Each circuit links one switching value output. If necessary, linking programming setting can be realized through the menu. Each product has one RS485 digital interface to communicate with the host computer;

● The visual range is farther and the visual angle is wider. Concentration contains 4 effective digits. Display with an accuracy of 9999~0.001 is available;

● Save the latest 999 alarming records and 999 failure records.

Structure

1. Side lock
2. Cover
3. Casing ground
4. User connection terminal
5. User connection terminal
6. Incoming hole
7. Bottom box
8. Power supply terminal
9. Switch of main power supply
10. Switch of standby power supply
11. Switch power supply
12. Standby battery
13. Battery holder
14. Horn
15. Control panel
16. Anti-collision mat

Panel Marks And Mounting Instructions


● Make 4 or 6 mounting holes (hole depth: ≥40mm) in a wall according to the requirements for the size among mounting holes (hole symbols 1 – 6) for mounting the hanging plate;

● Insert a plastic expansion bolt into each mounting hole;

● Fix the hanging plate onto the wall and fasten it onto the expansion bolts with 4 or 6 self-tapping screws (ST4.2×25);

● Hang the hanging parts at the bottom of the controller onto location A at the bottom board to complete mounting of the controller.

System Configuration

AEC2392b has 4 sets of branch-line connection terminals that can be connected to the branch-line communication equipment manufactured by the company such as detectors AEC2232b, AEC2232bX, GQ-AEC2232b, GQ-AEC2232bX and AEC2232aT, or other transmitters with 4~20mA signal outputs to monitor and control the gas concentration at site. Meanwhile, remote logical control over external equipment (in-situ audible-visual, solenoid valves and fans, etc.) can be realized through 5 sets of built-in programmable modules. In addition, remote communication with the monitor system can be realized through the RS485 communication interface.


Product detail pictures:

Professional China Combustible Gas Detection Controller - Gas Alarm Controller AEC2392b – Action detail pictures

Professional China Combustible Gas Detection Controller - Gas Alarm Controller AEC2392b – Action detail pictures


Related Product Guide:

Our pursuit and company intention is usually to "Always fulfill our purchaser requirements". We go on to acquire and layout excellent high quality products for both our previous and new consumers and realize a win-win prospect for our customers too as us for Professional China Combustible Gas Detection Controller - Gas Alarm Controller AEC2392b – Action , The product will supply to all over the world, such as: Iran, South Korea, India, Our team knows well the market demands in different countries, and is capable of supplying suitable quality products and solutions at the best prices to different markets. Our company has already set up a experienced, creative and responsible team to develop clients with the multi-win principle.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Johnny from Swiss - 2017.06.16 18:23
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.